Chapter 16 PLC Function Applications│CFP2000
API
MODRW
150
Bit device
X
Y
M
S1
S2
S3
S
n
 S1: online device address. S2: communications function code. S3: address of
data to read/write. S: register for data to be read/written is stored. N: length of data
to be read/written.
 COM1 must be defined as controlled by the PLC (set Pr.09-31 = -12) before using
this command, and the corresponding communications speed and format must
also be set (set Pr.09-01 and Pr.09-04). S2: communications function code.
Currently only supports the following function code; the remaining function code
cannot be executed.
 After executing this command, M1077, M1078 and M1079 will be immediately
changed to 0.
 As an example, when CFP2000 must control another converter and PLC, if the
converter has a station number of 10 and the PLC has a station number of 20, see
the following example:
Control slave device converter
Seria
l No.
P
Word device
K
H
KnX KnY KnM
Function
Description
H 02
Input read
H 03
Read word
H 06
Write single word
H 0F
Write multiple coils
H10
Write single word
Example
Reads 4 sets of data comprising the
converter slave device Pr.01-00 to
1
Pr.01-03, and saves the read data in
D0 to D3
Reads 3 sets of data comprising the
converter slave device addresses
2
H2100 to H2102, and saves the read
data in D5 to D7
Reads 3 sets of data comprising the
converter slave device Pr.05-00 to
3
Pr.05-03, and writes the values as D10
to D12
Writes 2 sets of data comprising the
converter slave device addresses
4
H2000 to H2001, and writes the values
as D15 to D16
Modbus data read/write
16-bit command (5 STEP)
T
C
D
MODRW
execution type
32-bit command
Flag signal:
S1
Node ID
K10
K10
K10
K10
16-102
Continuous
MODRW
P
execution type
M1077 M1078 M1079
MODRW command
S2
S3
S4
Function
Address Register
code
H3
H100
D0
H3
H2100
D5
H10
H500
D10
H10
H2000
D15
Pulse
n
Length
K4
K3
K3
K2