ID No.
Display on LCD Keypad
96
Action level
Action time
Warning setting parameter
Reset method
Reset condition
Record
Cause
KPC-CC01 is removed while
copying PLC program
ID No.
Display on LCD Keypad
101
Action level
Action time
Warning setting parameter
Reset method
Reset condition
Record
Cause
Malfunction caused by interference
Different communication
conditions with the upper unit
Communication cable break off or
not connected well
Warning Name
Copy PLC: time-out
Copy PLC time out
(CPLt)
Action and Reset
Software detection
Immediately acts
N/A
Manual reset
Directly resets
N/A
The KPC-CC01 cannot be removed during the PLC copy process
Warning Name
InrCOM time-out (ictn) Internal communication time-out
Action and Reset
When Pr.09-31= (-1) – (-10) (no -9) and the internal communication between
Master and Slave is abnormal, the ictn warning shows.
Immediately acts
N/A
Auto-reset
The warning automatically clears when the communication is back to normal
condition
N/A
Verify wiring/grounding of the communication circuit. It is recommended to
separate the communication circuit from the main circuit, or wire in 90 degree for
effective anti-interference performance.
Check if the setting for Pr.09-02 is the same as the setting for upper unit
Check the cable status or replace the cable