Delta CFP2000 Series User Manual page 62

Ip55 fan and pump drive
Table of Contents

Advertisement

Terminals for connecting DC reactor, external brake resistor and DC circuit
Connect a brake resistor or brake unit in applications with frequent deceleration
ramps, short deceleration time, too low brake torque or requiring increased brake
torque.
The external brake resistor of Frame A, B and C should connect to the terminals (B1,
B2) of AC motor drives.
For those models without built-in brake resistor, please connect external brake unit
and brake resistor (both of them are optional) to increase brake torque.
When the terminals +1/DC+ and -/DC- are not used, please leave the terminals open.
DC+ and DC- are connected by common DC bus, please refer to Section 5-1 (Main
Circuit Terminal) for the wiring terminal specification and the wire gauge information.
Please refer to the VFDB manual for more information on wire gauge when installing
the brake unit.
Chapter 5 Main Circuit TerminalsCFP2000
Figure 5-2
5-3