Delta CFP2000 Series User Manual page 500

Ip55 fan and pump drive
Table of Contents

Advertisement

ID*
Display on LCD Keypad
4
Action level
Action time
Fault treatment parameter
Reset method
Reset condition
Record
Cause
Motor burnout or aging insulation
occurred
Short circuit due to broken cable
Larger stray capacitance of the
cable and terminal
Malfunction caused by interference
Hardware failure
ID*
Display on LCD Keypad
5
Action level
Action time
Fault treatment parameter
Reset method
Reset condition
Record
Cause
IGBT error
Short-circuit detecting circuit error
Fault Name
When (one of) the output terminal(s) is grounded, short
circuit current is larger than Pr.06-60 setting value, and
the detection time is longer than Pr.06-61 time setting,
Ground fault (GFF)
GFF occurs.
NOTE: the short circuit protection is provided for AC
motor drive protection, not to protect the user.
Action and Reset
Pr.06-60 (Default = 60%)
Pr.06-61 (Default = 0.10 sec.)
N/A
Manual reset
Reset in 5 sec. after the fault is cleared
Yes
Check the motor insulation value with megger. Replace the motor if the
insulation is poor.
Troubleshoot the short circuit.
Replace the cable.
If the motor cable length exceeds 100 m, decrease the setting value for carrier
frequency.
Take remedies to reduce stray capacitance.
Verify the grounding and wiring of the communication circuit. It is recommended
to separate the communication circuit from the main circuit, or wire in 90 degree
for effective sufficient anti-interference performance.
Cycle the power after checking the status of motor, cable and cable length. If
GFF still exists, return to the factory for repair.
Fault Name
IGBT short circuit
Short-circuit is detected between upper bridge and
between upper bridge
lower bridge of the IGBT module
and lower bridge (occ)
Action and Reset
Hardware protection
Immediately act
N/A
Manual reset
Reset in 5 sec. after the fault is cleared
Yes
Check the motor wiring.
Cycle the power, if occ still exists, return to the factory for repair.
14-5
Chapter 14 Fault Codes and DescriptionsCFP2000
Fault Descriptions
Corrective Actions
Fault Descriptions
Corrective Actions

Advertisement

Table of Contents
loading

Table of Contents