ID No.
Display on LCD Keypad
68
Action level
Action time
Warning setting parameter
Reset method
Reset condition
Record
Cause
Malfunction caused by interference
The command from the upper unit
does not meet the CANopen
format
ID No.
Display on LCD Keypad
70
Action level
Action time
Warning setting parameter
Reset method
Reset condition
Record
Cause
The setting address exceeds the
range (0–63)
The speed setting exceeds the
range
The address is duplicated with
other nodes on the BUS
Warning Name
When the drive receives an incorrect packet, it means
CAN/M time-out
that there is interference or the command from the
(PCTo)
upper unit does not meet the CANopen command
format.
Action and Reset
N/A
Immediately acts when receiving the command
N/A
The warning automatically clears after receives another normal packet
N/A
N/A
1. Verify wiring/grounding of the communication circuit. It is recommended to
separate the communication circuit from the main circuit, or wire in 90
degree for effective anti-interference performance.
2. Make sure the communication circuit is wired in series.
3. Use CANopen cable or add terminating resistance.
Please contact Delta for further confirmation.
Warning Name
Duplicate MAC ID error
ExCom ID fail (ECid)
Node address setting error
Action and Reset
Duplicate setting of MAC ID
Node address setting error
N/A
N/A
Correct the setting and cycle the power
N/A
N/A
Check the address setting of the communication card (Pr.09-70)
Standard: 0–2, non-standard: 0–7
Reset the address
13-33
Chapter 13 Warning CodesCFP2000