Delta CFP2000 Series User Manual page 528

Ip55 fan and pump drive
Table of Contents

Advertisement

ID*
Display on LCD Keypad
63
Action level
Action time
Fault treatment parameter
Reset method
Reset condition
Record
Cause
Any of the motor parameters in
parameter group 5 may be
incorrect
Overload
Any of the setting value of
Pr.07-29, 07-30, and 10-29 is
improper
ID*
Display on LCD Keypad
64
Action level
Action time
Fault treatment parameter
Reset method
Reset condition
Record
Cause
The input power is abnormal
Malfunction caused by interference Verify the wiring/grounding of the main circuit to prevent interference.
Hardware failure
Fault Name
On the basis of the maximum slip limit set via Pr.10-29,
the speed deviation is abnormal. When the motor drive
outputs at constant speed, F>H or F<H exceeds the
Over slip error (oSL)
level set via Pr.07-29, and it exceeds the time set via
Pr.07-30, oSL shows. oSL occurs in induction motors
only.
Action and Reset
Pr.07-29
100% of Pr.07-29 = the maximum limit of the slip frequency (Pr.10-29)
Pr.07-30
Pr.07-31
0: Warn and continue operation
1: Fault and ramp to stop
2: Fault and coast to stop
3: No warning
Pr.07-31=0 is a warning.
When the motor drive outputs at constant speed, and F>H or F<H
Auto
does not exceed the level set via Pr.07-29 anymore, oSL warning will
be cleared automatically.
Hand
When Pr.07-31=1 or 2, oSL is an error, and it needs to reset manually.
Immediately reset
Pr.07-31=1 or 2, oSL is "Fault", and will be recorded.
Check the motor parameters
Decrease the load
Check the setting of oSL protection function related parameters
Fault Name
Electric valve switch
Electric valve switch error when executing Soft Start
error (ryF)
Action and Reset
Hardware detection (Frame D and above)
Immediately act
N/A
Manual reset
Reset when the electric valve switch is correctly closed
Yes
Check if the power is shut down during the drive operation.
Check if the three-phase input power is normal.
Cycle the power after checking the power. If ryF error still exists, return to the
factory for repair.
14-33
Chapter 14 Fault Codes and DescriptionsCFP2000
Fault Descriptions
Corrective Actions
Fault Descriptions
Corrective Actions

Advertisement

Table of Contents
loading

Table of Contents