4 Connection

4.4.4 Connecting FCUA-DX141 Unit with Analog Input/Output Signal

For the analog input/output signal, connect the FCUA-R031 cable to "AIO". Up to four input points and one output point
can be connected for the analog input/output signal. When manufacturing the FCUA-R031 cable, use the FCUA-CS000
connector set (optional, with both ends).
FCUA-R031
Analog I/F
Input/output circuit
Connector pin No.
AI0
2
AI1
12
Input
AI2
3
AI3
13
A0
7
Output
GND
1
GND
11
G ND
5
GND
15
CAUTION
1. Connect the cable to the designated connector. Incorrect connections could damage the device.
2. Do not connect or disconnect the connection cables between each unit while the power is ON.
108
AIO
FCUA-DX141
150
150
150
150
R
R
220
0V (RG)
0V (RG)
FCUA-DX141
20
11
ADC
DAC
10
1
Pin No.