13 Spindle Control

13.1 Related Parameters

Spindle speed can be directly controlled by an 8-digit S code command.
When the S command function specifications are valid, the controller selects an appropriate spindle gear stage corresponding
to the 8-digit command following the S code and outputs (spindle gear shift command) it to the machine side (PLC). The
controller also outputs S command data (analog voltage or serial connection data) corresponding to the gear input (spindle
gear select input) and spindle speed specified by the machine side (PLC).
13.1 Related Parameters
The PLC can have up to four gear stages.
The table below lists the four gear stages and the corresponding parameters.
Spindle
Parameter name
limit
speed
Gear stage
Slimt1
1
#3001
Slimt2
2
#3002
Slimt3
3
#3003
Slimt4
4
#3004
Note
(1) The upper line shows the parameter name, and the bottom line shows the parameter No.
(2) Set the parameter for the gear stage not being used to "0".
IB-1501668-B
Parameters
Maximum
Tap cycle
Spindle
spindle
maximum
shift speed
speed
speed
Smax1
Ssift1
Stap1
#3005
#3009
#3013
Smax2
Ssift2
Stap2
#3006
#3010
#3014
Smax3
Ssift3
Stap3
#3007
#3011
#3015
Smax4
Ssift4
Stap4
#3008
#3012
#3016
Output sig-
Oriented
Minimum
nal
speed
speed
GR2 GR1 GI1
0
0
0
1
Sori
Smin
#3021
#3023
1
0
1
1
490
Input signal
GI2
0
0
0
1
1
0
1
1