3.1 General Specification

(1) Environment conditions in operation box
Type name
Unit name
Ambient
temperature
Ambient
humidity
Vibration resistance
Shock resistance
Working atmosphere
Power voltage
Momentary stop tolerance time
Current consumption
Heating value
Weight
Unit size
(∗1) When using the model with built-in hard disk (FCU6-MU5
temperature in the panel is 5°C or less when the power is turned ON.
The hard disk will start up automatically after the hard disk temperature has risen to 5°C with the heater.
(∗2) The display quality (contrast/hues) will drop at 45°C and above.
With the FCU6-DUC3
(2) Environment conditions in electric cabinet
Type name
Unit name
Ambient
temperature
Ambient
humidity
Vibration resistance
Shock resistance
Working atmosphere
Power voltage
Current consumption
Heating value
Weight
Unit size
CHAPTER 3 INSTALLATION
3.1 General Specification
0~55°C (∗1: Working temperature
During operation
During storage
During operation
During storage
(color STN) model, the surface temperature is up to 40°C.
During operation
During storage
During operation
During storage
MCU6-MU
Control unit
5~55°C)
−20~60°C
45~75% RH (with no dew condensation)
45~80% RH (with no dew condensation)
0.5G or less (during operation)
3G or less (during operation)
No corrosive gas, dust and oil mist
24VDC±5% Ripple ±5% (P-P)
20ms (when using external power supply unit)
3A (max.)
31W (typ.) 72W (max.)
3.5kg
Refer to appendix.
), the hard disk will not start up if the
HR361/HR371
Card size I/O
0~55°C
−20~60°C
45~75% RH (with no dew condensation)
45~80% RH (with no dew condensation)
0.5G or less (during operation)
3G or less (during operation)
No corrosive gas, dust and oil mist
24VDC±5%
Ripple ±5% (P-P)
5V 0.4A 24V 1.2A (∗1)
15W (∗3)
300g
Refer to appendix.
7
MCU6-DUN3
/DUC3
/DUT3
Display unit
0~50°C (Display unit surface
temperature)(∗2)
PD25
External power supply unit
200~230VAC +10% −15%
50/60Hz ±1Hz
0.6A
35W
1.5kg