Replacing The Limit Sensor And The X-Axis Home Position Sensor; Replacing The Xl-, Xr-, And Xc-Limit Sensors; Replacing The Yb- +/−Limit Sensors And Yb-Near Sensor - JUKI FX-1 Maintenance Manual

High-speed modular mounter
Table of Contents

Advertisement

FX-1/FX-1R Maintenance Manual

1-5. Replacing the Limit Sensor and the X-Axis Home Position Sensor

(1) If only the sensor is replaced, it is not necessary to adjust the position.
(2) If the sensor is replaced together with the bracket, it is necessary to adjust the position. (X-axis
only)
1-5-1. Replacing the XL-, XR-, and XC-limit sensors, XL- and XR-near sensors, XL- and
XR-ORG sensors
XL -Limit Sensor ASM: L811E8210A0
XL Near Sensor ASM: L811E7210A0
XL ORG Sensor ASM: L813E6210A0
XC Limit Sensor ASM: L811E9210A0
(1) For mounting positions of the XL- and XR-sensors, the distance between the end of the
X-beam and the XL- and XR-sensor bracket must be 209.5 mm.
(2) The XC-limit sensor bracket is mounted so that it is projected 15 mm from the end of the
XM-base.
(3) When the distance between each rubber stopper and the XM-base becomes 5 mm, make the
adjustment so that each limit sensor is turned ON, and then fix the sensor with the screw.
1-5-2. Replacing the YB- +/−limit sensors and YB-near sensor
(1) Since the Y-axis bracket is fixed by the cross-recessed flat head screws, no adjustments are
required.
YBL -LIMIT SENSOR ASM: L811E1210A0
YBL +LIMIT SENSOR ASM: L811E3210A0
YB NEAR SENSOR ASM: L811E5210A0
XR +Limit Sensor ASM: L812E1210A0
XR Near Sensor ASM: L812E0210A0
XR ORG Sensor ASM: L813E7210A0
Figure 1-5-1-1
1-8
Rev. 2.00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx-1r