Sticking The Label; Adjusting The Hms Height - JUKI KE-1070 Maintenance Manual

High-speed chip scooter
Table of Contents

Advertisement

3-3-3. Sticking the Label

After the label sticking surface has been degreased, stick the label.

3-3-4. Adjusting the HMS Height

Move the HMS sensor to a point above the calibration block. Loosen the SEMS cap bolts at two
places so that the distance between the bottom surface of the height sensor and the top surface
of the calibration block becomes 40
indicators are lit. When the specified distance is reached, secure the bad mark sensor with SEMS
cap bolts.
Top surface of the calibration block
After the sensor height has been adjusted, input the MS parameters related to the bad mark
sensor offset. For details about how to input MS parameters, see "MS Parameters".
CAUTION
Maintenance Guide
Figure 3-3-3 Replacing the Amplifier
(Left: label/right: label stuck)
0.2 mm. At this time, check that both the FAR and NEAR
Range indicator: lighting status
NEAR/FAR
NEAR
FAR
NEAR/FAR
To prevent personal injury, do not put your hand inside the machine
or your face or head close to the machine during operation of the
HOD.
3-9
FAR
Both are lit: Measurement center distance ± 1 mm
Light on: Near side within measurement range
Light on: Far side within measurement range
Both are flashing: Beyond measurement range
NEAR

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ke-1070cKe-2070cKe-2070Ke-1080Ke-2080Ke-2080r

Table of Contents