Siemens Sinumerik 840D sl Function Manual page 700

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Diagnostics
10.2 NCK safety alarms for Sinumerik 840D sl
Response
Remedy
Program
r
continuation
27091
Parameter
Explanation
Response
Remedy
Program
r
continuation
10-700
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
-- 257...320: Error in system variables $A_MARKERSI[1...64]
-- 321...448: Error in system variables $A_INSE[65...192]
-- 449...576: Error in system variables $A_OUTSE[65...192]
-- 577...704: Error in system variables $A_INSI[65...192]
-- 705...832: Error in system variables $A_OUTSI[65...192]
-- 833...960: Error in system variables $A_MARKERSI[65...192]
Alarm display
A STOP D/E is initiated (this can be set using MD10097
$MN_SPL_STOP_MODE) on all of the axes with safety functionality if
the SPL commissioning phase (MD11500 $MN_PREVENT_SYN-
ACT_LOCK[0,1] not equal to 0) has been completed.
Analyze the displayed value and evaluate DB18: SPL_DELTA on the
PLC side.
Find the difference between the monitoring channels.
Possible causes:
-- Incorrect wiring
-- Incorrect SPL
-- The axis--specific SGEs have been incorrectly assigned to the
internal interface $A_OUTSI
-- The axis--specific SGAs have been incorrectly assigned to the
internal interface $A_INSI
-- The SPL--SGEs have been incorrectly assigned to the external
interface $A_INSE
-- The SPL--SGAs have been incorrectly assigned to the external
interface $A_OUTSE
-- Different SPL commissioning status has been set in the NCK and
PLC
-- Different SPL stop response has been set in the NCK and PLC
Clear the alarm with the RESET key. Restart the part program.
Error for crosswise data comparison, NCK- -PLC, STOP of %1
%1 = supplementary information about the monitoring channel that has
initiated the stop
The monitoring channel specified in %1 (NCK or PLC) has initiated a
STOP D or E (depending on the parameterization in MD10097
$MN_SAFE_SPL_STOP_MODE). Alarm 27090 provides additional
information about the reason for the Stop D/E.
Alarm display
A STOP D/E is initiated (this can be set using MD10097
$MN_SPL_STOP_MODE) on all of the axes with safety functionality if
the SPL commissioning phase (MD11500 $MN_PREVENT_SYN-
ACT_LOCK[0,1] not equal to 0) has been completed.
Evaluate the alarm parameters of Alarm 27090 and correct the SPL, or
check the internal SPL interfaces to the safety monitoring channels in
the NCK and drive.
Clear the alarm with the RESET key. Restart the part program.
© Siemens AG 2015 All Rights Reserved
10/15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents