Siemens Sinumerik 840D sl Function Manual page 789

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

10/15
F30651
Response
Acknowledgment
Explanation
Remedy
F30652
Response
Acknowledgment
Explanation
Remedy
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
For fault value = 2000:
-- Check the safety parameters in the monitoring channel 2 and adapt
the reference checksum (p9899).
For fault value = 2003, 2005:
-- Carry out acceptance test and create test certificate.
The procedure when carrying out the acceptance test as well as an
example for the acceptance report can be found in the following
reference:
SINAMICS S120 Safety Integrated Function Manual
For fault value = 9999:
-- Carry out diagnostics for the other safety--related fault that is
present.
See also: p9799 (SI reference checksum SI parameters (Control Unit)),
p9899 (SI reference checksum, SI parameters (Motor Module)).
SI P2: Synchronization with the Control Unit unsuccessful
OFF2
IMMEDIATELY (POWER ON)
The "Safety Integrated" function integrated in the drive requires that the
safety time slices are synchronized in both monitoring channels. This
synchronization routine was not successful.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Carry out a POWER ON (power off/on) for all components
-- Upgrade the Motor Module/Hydraulic Module software.
-- Upgrade the Control Unit software.
SI P2: Monitoring clock cycle not permissible
OFF2
IMMEDIATELY (POWER ON)
The Safety Integrated monitoring clock cycle cannot be maintained due
to the communication conditions requested in the system.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
When fault F01652 simultaneously occurs, apply the remedy/counter-
measure described there.
-- Upgrade the firmware of the Motor Module/Hydraulic Module to a
later version.
10.3Safety messages for SINAMICS S120
Diagnostics
10-789

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents