Siemens Sinumerik 840D sl Function Manual page 727

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

10/15
Response
Remedy
Program
r
continuation
27254
Parameter
Explanation
Response
Remedy
Program
r
continuation
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
A STOP D/E is initiated (this can be set using MD10097
$MN_SAFE_SPL_STOP_MODE) on all axes with safety functionality.
Stop of the PROFIsafe driver involved. Stopped PROFIsafe driver of
type F--DI or F--DIO F modules -- output fail--safe values (0) towards
the SPL as F net data.
Extend the PROFIsafe cycle time using MD10098 $MN_PROFI-
SAFE_IPO_TIME_RATIO.
Remove the fault. After changing the F clock cycle, POWER ON
PROFIsafe: F module %1, error on channel %2; %3<ALSI>
%1 = PROFIsafe address or name
%2 = channel type, channel number
%3 = supplementary info, system variables -- field index
The F module signals that an error has occurred in the interface of the
specified channel. The alarm is only triggered for ET200 F modules.
The type of channel (input or output channel) is displayed in %2 using
the IN and OUT abbreviation).
Using parameter %3, a specific alarm message can be configured on
the HMI for each of the listed system variables
-- 1....64: Error in system variables $A_INSE[1...64]
-- 65...128: Error in system variables $A_OUTSE[1...64]
-- 321...448: Error in system variables $A_INSE[65..192]
-- 449...576: Error in system variables $A_OUTSE[65..192]
-- --1: Error in the input or output channel for which there is no SPL
assignment.
Mode group not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
A STOP D/E is initiated (this can be set using MD10097
$MN_SAFE_SPL_STOP_MODE) on all axes with safety functionality.
Check the wiring. Wiring OK: Replace the F module.
Remove the error and press RESET.
10.2NCK safety alarms for Sinumerik 840D sl