-- Check whether there is a DRIVE--CLiQ communications error
between the Control Unit and the Motor Module involved and if
required, carry out a diagnostics routine for the faults identified.
For fault value = 5022:
-- Check the value settings of the F parameters at the PROFIsafe
slave (F_SIL, F_CRC_Length, F_Par_Version, F_Source_Add,
F_Dest_add, F_WD_Time).
For fault value = 5026:
-- Check the value settings of the F parameters and the F parameter
CRC (CRC1) calculated from this value at the PROFIsafe slave and
update.
For fault value = 5065:
-- Check the configuring and communication at the PROFIsafe slave
(Consecutive No./ CRC).
-- Check the value setting of the F parameter F_WD_Time at the
PROFIsafe slave and possibly increase.
-- Check whether there is a DRIVE--CLiQ communications error
between the Control Unit and the Motor Module involved and if
required, carry out a diagnostics routine for the faults identified.
For fault value = 5066:
-- Check the value setting of the F parameter F_WD_Time at the
PROFIsafe slave and possibly increase.
For fault value = 6000, 6072:
-- Carry out a POWER ON (power off/on) for all components.
-- Check whether there is a DRIVE--CLiQ communications error
between the Control Unit and the Motor Module involved and if
required, carry out a diagnostics routine for the faults identified.
-- Upgrade firmware release.
-- Contact the Hotline.
-- Replace the Control Unit.
For fault value = 6064:
-- Check the value setting in the F parameter F_Dest_Add at the
PROFIsafe slave.
-- Check the setting of the PROFIsafe address of the Control Unit
(p9610) and that of the Motor Modules (p9810).
For fault value = 6065:
-- Check the value setting in the F parameter F_Dest_Add at the
PROFIsafe slave. The target address must not be 0 or FFFF!
For fault value = 6066:
-- Check the value setting in the F parameter F_Source_Add at the
PROFIsafe slave. The source address must not be 0 or FFFF!
For fault value = 6067:
-- Check the value setting in the F parameter F_WD_Time at the
PROFIsafe slave. The watchdog time value must not be 0!
For fault value = 6068:
-- Check the value set in the F parameter F_SIL at the PROFIsafe
slave. The SIL must correspond to SIL2!
10.3Safety messages for SINAMICS S120
Diagnostics
10-773