MD number
Default value: 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
$MN_SAFE_MODE_MASK
'Safety Integrated' operating modes
Min. input limit: 0
Protection level: 7/2
Bit 1=0: The "Modular PROFIsafe I/O interface" function is not active.
Bit 1=1: The "Modular PROFIsafe I/O interface" function is active.
Bit 2=0: The reduced language scope for SAFE.SPF is only activated for an automatic start
when booting (MD20108 $MC_PROG_EVENT_MASK bit 5)
Bit 2=1: The reduced language scope for SAFE.SPF is also activated if SAFE.SPF is called
using the CALL command
Bit 3=0: all PROFIsafe drivers in one IPO clock cycle
Bit 3=1: PROFIsafe driver distributed over several IPO clock cycles
Bit 4=0: in safety operating mode "SINUMERIK Safety Integrated (SPL)", it is not possible
to couple NC axes to the drive monitoring functions via SIC/SCC
Bit 4=1: in safety operating mode "SINUMERIK Safety Integrated (SPL)", it is permissible to
couple NC axes to the drive monitoring functions via SIC/SCC
Bit 1:
MD13302 $MN_PROFISAFE_IN_ENABLE_MASK
MD13303 $MN_PROFISAFE_OUT_ENABLE_MASK
Bit 2:
MD20108 $MC_PROG_EVENT_MASK, bit 5
8.1 Machine data for SINUMERIK 840D sl
Max. input limit: 0x001E
Data Description
Unit: - -
8-359