10/15
13301381
MD number
Default value FFFFFFFFH
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional references
13302
MD number
Field index 0: Standard value 0
Field index 1: Standard value 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional references
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
$MN_PROFISAFE_OUT_FILTER[0...47]
F net (useful) data filter OUT
Min. input limit: 0
Protection level: 7/2
Filter between $A_OUTSE variables and F net (useful) data
The machine data is used to define in which F net data bits the $A_OUTSE[n] variables are
transferred.
Machine data MD10389 $MN_PROFISAFE_OUT_ASSIGN is used to define which
$A_OUTSE[n] variables are transferred into the F net data bits of the PROFIsafe module.
Example:
Note: For reasons of simplicity, only 16 bits are taken into consideration.
Parameter assignment:
$MN_PROFISAFE_OUT_FILTER = 1010100101000100
$MN_PROFISAFE_OUT_ASSIGN = 011006
n = 16
11
6
|x|x|x|x|x|1|1|1|1|1|1|x|x|x|x|x|
example of a value available at the $A_OUTSE variables, x = not relevant
|0|0|0|0|0|0|0|0|0|0|1|1|1|1|1|1|
NCK internal F net data image
|1|0|1|0|1|0|0|1|0|1|0|0|0|1|0|0|
$MN_PROFISAFE_OUT_FILTER
|1|0|1|0|1|0|0|1|0|1|0|0|0|1|0|0|
F net data of the PROFIsafe module
$MN_PROFISAFE_IN_ENABLE_MASK[0...1]
Enable screen form of the connections to PROFIsafe input modules
Min. input limit: 0
Min. input limit: 0
Protection level: 7/2
The machine data sets of the PROFIsafe connections to PROFIsafe input modules are
enabled using the enable screen forms.
A machine data set includes the following data:
- - MD10386 $MN_PROFISAFE_IN_ADDRESS[n]
- - MD10388 $MN_PROFISAFE_IN_ASSIGN[n]
- - MD13300 $MN_PROFISAFE_IN_FILTER[n]
- - MD13305 $MN_PROFISAFE_IN_SUBS[n]
Bit n = 0
The machine data set [n] is checked for consistency, but is however not active.
The PROFIsafe connection [n] or the slot [n] is inactive.
Bit n = 1
The machine data set [n] is active.
The PROFIsafe connection [n] or the slot [n] is active.
MD10095 $MN_SAFE_MODE_MASK, bit 1
MD13304 $MN_PROFISAFE_IN_SUBS_ENAB_MASK
8.1 Machine data for SINUMERIK 840D sl
Max. input limit: FFFFFFFFH
1
Max. input limit: FFFFFFFFH
Max. input limit: 0000FFFFH
Data Description
Unit: - -
Unit: - -
8-369