Siemens Sinumerik 840D sl Function Manual page 746

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Diagnostics
10.3 Safety messages for SINAMICS S120
Remedy
10-746
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
2005:
Feedback signal of the safe pulse cancellation on the Control Unit
and Motor Modules connected in parallel are different.
6000:
A critical error has occurred in the PROFIsafe communication.
6064..
Error when evaluating F parameters. The values of the transferred F
6071:
parameters do not coincide with the values expected in the PROFI-
safe driver.
6064:
Target address and PROFIsafe address differ (F_Dest_Add).
6065:
Target address invalid (F_Dest_Add).
6066:
Source address invalid (F_Source_Add).
6067:
Watchdog time value invalid (F_WD_Time).
6068:
Incorrect SIL level (F_SIL).
6069:
Incorrect F--CRC length (F_CRC_Length).
6070:
Incorrect F parameter version (F_Par_Version).
6071:
CRC error for the F parameters (CRC1). The transferred CRC value
of the F parameters does not match the value calculated in the
PROFIsafe driver.
6072:
F parameterization is inconsistent.
6165:
When receiving the PROFIsafe telegram, a communication error was
detected. The fault can also occur, if after switching off and switching
on the Control Unit -- or after inserting the PROFIBUS--/PROFINET
cable -- an inconsistent or out of date PROFIsafe telegram was
received.
6166:
When receiving the PROFIsafe telegram, a time monitoring error
(watchdog) was detected.
Re fault value = 1 to 5 and 7 to 999:
-- Check the crosswise compared data that resulted in a STOP F.
-- Carry out a POWER ON (power off/on) for all components.
-- Upgrade the Motor Module software.
-- Upgrade the Control Unit software.
For fault value = 6:
-- Carry out a POWER ON (power off/on) for all components.
-- Upgrade the hydraulic module software.
-- Upgrade the Control Unit software.
For fault value = 1000:
-- Check the EP terminal at the Hydraulic Module (contact problems).
-- PROFIsafe: Resolve problems/faults at the PROFIBUS master/
PROFINET controller.
© Siemens AG 2015 All Rights Reserved
10/15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents