10/15
Table 9-1
Recommendations for the scope of the acceptance test depending on specific measures
Measure
Documentation
Expanded func-
Inclusion of the
tionality or new
SI function per
functions (e.g.
axis, function
additional actua-
table
tor, additional SG
level)
SPL change
Inclusion of the
SI function per
axis, function
table
Data transferred
Supplement
to additional
machine
machines with
description
series commis-
(check the
sioning
software
version)
1
Regarding the acceptance test, the notes in the documentation of the SW upgrade must be carefully
observed.
2
An update involves an update to a new Service Pack (SP) or a new Hotfix (HF) within a software line, e.g.
02.05.01.03 (01 = Service Pack; 03 = Hotfix) to 02.05.02.03 (does not take into account any change of the
Safety functionality).
3
An upgrade involves an upgrade to a new software release, e.g. 02.05.xx.xx to 02.06.xx.xx or 02.xx.xx.xx.
to 03.xx.xx.xx (does not take into account any change of the Safety functionality).
4
If no checksums have changed, then a complete function test, Part 2 does not have to be performed.
However, a test should be performed with reduced testing scope.
Test with reduced test scope
Test of Safety Integrated functions at any axis (each NCU and each NX) and a comparison with the test results
before the upgrade.
Note:
If the results of function test, Part 2 are taken from another identical machine, then this is the sole responsibility
of the machine manufacturer and should be appropriately commented in the acceptance report.
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Function
Function
test
test
Part 1
Part 2
Yes, only for
Yes, only
the tests
for the
influenced
tests
by the func-
influenced
tion expan-
by the
sion
function
expansion
Yes, only
No
Point 2.6
Yes
No
Commissioning
9.5 Acceptance test
Supplemen-
Report
tary
completion
measures
No
Document changed
checksum
No
Document changed
checksum
Points 4.1 and
Document changed
4.5
checksum
9-579