10/15
Response
Remedy
Program
r
continuation
27222
Parameter
Explanation
Response
Remedy
r
Program
continuation
27223
Parameter
Explanation
Response
Remedy
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Check the PROFIsafe addresses in the NCK--MD and S7--I/O
(peripherals) configuration
Switch control system OFF and ON again.
PROFIsafe: S7 F module PROFIsafe address %1 unknown
%1 = PROFIsafe address
The F module with the specified PROFIsafe address has not been
parameterized as an F module in the NCK MD
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Check the S7 PROFIBUS configuration. Register the module in the
NCK MD
Switch control system OFF and ON again.
PROFIsafe: NCK F module MD %1[%2] is not a %3 module
%1 = MD name
%2 = MD field index
%3 = module type
The F module parameterized in the specified NCK MD has not been
designated as an appropriate input/output module in the S7 PROFIBUS
configuration.
-- %3 = INPUT: NCK F parameterization expects an INPUT module
-- %3 = OUTPUT: NCK F parameterization expects an OUTPUT
module
-- %3 = IN/OUT: NCK F parameterization expects an INPUT/OUTPUT
module
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Check the module in the S7 PROFIBUS configuration
10.2NCK safety alarms for Sinumerik 840D sl