10/15
Program
r
continuation
27090
Parameter
Explanation
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Switch--off – switch--on the control
Error for crosswise data comparison NCK- -PLC %1 [%2], NCK:
%4<ALSI>
%3;
%1 = name of the system variable in which the error was detected
%2 = supplementary info, system variables -- field index
%3 = supplementary information, comparison value, NCK
%4 = supplementary information, crosswise data comparison -- field
index
For cyclic crosswise data comparison between the NCK and PLC
differences have occurred in the data that are being compared. Para-
meter %1 specifies the incorrect system variable ($A_INSI, $A_OUTSI,
$A_INSE, $A_OUTSE or $A_MARKERSI) with field index %2.
Special situations:
-- Display "Error for crosswise Data comparison NCK--PLC,
$MN_PREVENT_SYNACT_LOCK[0], ..." means that the SPL
commissioning status is set differently in the NCK and PLC.
-- Display "Error for crosswise Data comparison NCK--PLC,
$MN_SPL_STOP_MODE[0], ..." means that the SPL stop response
(Stop D or E) is set differently in the NCK and PLC.
-- Display "Error for crosswise data comparison NCK--PLC, TI-
MEOUT[0], NCK: 0" means that there is a communication error
between NCK and PLC, and no crosswise data comparison can be
performed.
-- Display "Error for crosswise data comparison NCK--PLC,
$MN_SAFE_SPL_USER_DATA[n], ..." means that the user data are
set differently in the NCK and PLC.
-- Display "Error for crosswise Data comparison NCK--PLC,
$A_FRDP_SUBS[n], $A_FRDP_ERR_REAC[n], ..." means that the
specified system variables are different in the NCK and PLC.
Using parameter %4, a specific alarm message can be configured on
the HMI for each of the listed system variables:
-- 0: Error SPL commissioning status ($MN_PREVENT_SYN--
ACT_LOCK[0,1] -- SPL_READY)
-- 0: Error, SPL stop response
($MN_SAFE_SPL_STOP_MODE -- STOP E)
-- 0: Error, SPL user data
($MN_SAFE_SPL_USER_DATA -- SafeUserData)
-- 0: Error FSENDDP error response ($A_FSDP_ERR_REAC[n] --
FSDP_ERR_REAC
-- 0: Error FRECVDP error response ($A_FRDP_ERR_REAC[n] --
FRDP_ERR_REAC
-- 0: Error FRECVDP substitute values ($A_FRDP_SUBS[n] --
FRDP_SUBS
-- 1...64: Error in system variables $A_INSE[1...64]
-- 65...128: Error in system variables $A_OUTSE[1...64]
-- 129...192: Error in system variables $A_INSI[1...64]
-- 193...256: Error in system variables $A_OUTSI[1...64]