System Features
3.1 System requirements
S SINUMERIK 840D sl; all NCU types can be used
S The measuring circuit cables must comply with the specifications of the SINA-
MICS S120
S Safety--related devices/modules, that correspond to open--type devices accor-
ding to UL 50, may only be operated in enclosure--type housings/cabinets that
have as a minimum degree of protection IP54 in accordance with EN 60529.
Further, chassis units with degree of protection IP20 and IPXXB should be ope-
rated corresponding to EN 60529 in higher--level enclosures.
S The state of a deleted/clear safety--related input or output (i.e. the state logical
"0" of an SGE/SGA and electrical "low" of an associated I/O terminal) or the
state of a drive where the pulses are cancelled that can be achieved by the
user as well by the fault response of the "SINUMERIK Safety Integrated" sy-
stem, is defined as the so--called "fail--safe state". This is the reason that the
system is only suitable for applications where this state corresponds to the safe
state of the process controlled by SINUMERIK Safety Integrated.
S Drives with slip cannot be used for SE and SN.
S The SINUMERIK Safety Integrated functions can be used in conjunction with
the SINAMICS booksize and chassis units (max. 2 units).
S For the Safety Integrated function, only the explicitly released encoder systems
may be used. A list of the Siemens encoders and motors permissible for Safety
Integrated functions can be obtained from your local Siemens contact partner.
S SINUMERIK Safety Integrated can be operated with a maximum of two chassis
units.
The following applies specifically for safety functions integrated in the drive:
S A software option is not required when using the SINAMICS Safety Integrated
Basic Functions.
The following specifically applies for fail--safe SIMATIC modules:
S STEP7 F configuration tool (F Configuration Pack) as supplement to STEP7
This F configuration tool is required so that ET 200 F modules or the DP/AS--i
F--Link can be integrated into the HW configuration.
The F configuration tool can be downloaded from the A&D Service&Support
pages under the topic F- -Configuration- -Pack. Which F configuration tool can
be used for which STEP7 version is also specified there.
http://support.automation.siemens.com/WW/view/en/15208817
When using ET 200 F modules or DP/AS--i F--Link it should be noted that a
version of the F configuration tool should be used that the module already
supports.
Which modules can be configured with which versions that can be downloaded
are also specified in the download area.
Note
Only the F--Configuration Pack is necessary to connect fail--safe SIMATIC
modules to SINUMERIK. Neither SIMATIC S7 Distributed Safety nor SIMATIC S7
F systems are required.
3-42
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
© Siemens AG 2015 All Rights Reserved