Siemens Sinumerik 840D sl Function Manual page 697

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

10/15
Explanation
Response
Remedy
Program
r
continuation
27070
Explanation
Response
Remedy
Program
r
continuation
27071
Explanation
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
The axis--specific MD $MA_SAFE... and MD10393
$MN_SAFE_DRIVE_LOGIC_ADDRESS are protected by a checksum.
The alarm indicates that the actual checksum no longer matches the
saved checksum, i.e. that either a piece of data was illegally changed
or is corrupt.
In the commissioning phase (SPL commissioning mode active), instead
of the individual axis--specific checksum alarms (27032, 27035 and
27060), the axis--specific group alarm 27132 is displayed. MD10094
$MN_SAFE_ALARM_SUPPRESS_LEVEL can be used to further
reduce the alarm display so that only one alarm is displayed for all axes
(global group alarm 27135).
Alarm display
Interface signals are set
NC start disable in this channel
NC stop for alarm
Mode group not ready
Channel not ready
Check the machine data, recalculate the checksum and confirm.
Re--accept the safety functions (connections, NCK axis -- drive
encoder).
Switch--off – switch--on the control
Checksum error parameterization SPL and SPL interfaces.
Confirmation and acceptance test required!
The NCK--MD to parameterize the SPL I/O and SPL functionality (also
including $MN_PROFISAFE..., MD133xx/134xx $MN_SAFE_SDP/
RDP...) are protected using a checksum. The alarm indicates that the
actual checksum no longer matches the saved checksum, i.e. that
either a piece of data was illegally changed or is corrupt.
Alarm display
Interface signals are set
NC start disable in this channel
NC stop for alarm
Mode group not ready
Channel not ready
Check the machine data, recalculate the checksum and confirm. Re--
accept the safety functions (PROFIsafe I/O, SPL I/O, FSEND/FRECV).
Switch--off – switch--on the control
Checksum error safe SPL parameterization. Confirmation and
acceptance test required!
The NCK--MD13312 $MN_SAFE_SPL_USER_DATA is protected by a
checksum. The alarm indicates that the actual checksum no longer
matches the saved checksum, i.e. that either a piece of data was
illegally changed or is corrupt.
10.2NCK safety alarms for Sinumerik 840D sl
Diagnostics