10/15
r9771
SI common functions (Control Unit)
Displays the Safety Integrated monitoring functions supported on the Control
Unit and Motor Module.
The Control Unit determines this display.
Bit 00: STO via terminals is supported
1 signal: Yes, 0 signal: No
Bit 01: SBC supported
1 signal: Yes, 0 signal: No
Bit 02: SS1 delay time active on the control unit active
1 signal: Yes, 0 signal: No
Bit 03: SS1 supported
1 signal: Yes, 0 signal: No
Bit 08: 08 Safe Brake Adapter supported
1 signal: Yes, 0 signal: No
Bit 13: ESR delay of the pulse cancellation supported
1 signal: Yes, 0 signal: No
Unit:
Default value:
- -
- -
r9773.0...31
CO/BO: SI Status (Control Unit + Hydraulic Module)
Displays the Safety Integrated status on the drive (Control Unit + Motor Mo-
dule).
Bit 00: STO selected in the drive
Bit 01: STO active in the drive
Bit 02: SS1 active in the drive
Bit 04: SBC requested
: SS1 selected in the drive
Bit 05
: SS1 active in the drive
Bit 06
Bit 31: Shutdown path test required
This status is formed from the AND operation of the relevant status of the two
monitoring channels.
Unit:
Default value:
- -
- -
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Minimum value:
Maximum value:
- -
- -
1 signal: Yes, 0 signal: No
1
signal: Yes, 0 signal: No
1 signal: Yes, 0 signal: No
1
signal: Yes, 0 signal: No
1
signal: Yes, 0 signal: No
1
signal: Yes, 0 signal: No
1 signal: Yes, 0 signal: No
Minimum value:
Maximum value:
- -
- -
Data Description
8.2 Parameters for SINAMICS S120
Checksum:
No
Data type:
Unsigned32
Checksum:
No
Data type:
Unsigned32
Protection level:
3
Effective:
--
Protection level:
2
Effective:
--
8-475