Data Description
8.2 Parameters for SINAMICS S120
r10242
SI Motion SBT state diagnostics
Displays the current status of the safe brake test.
0: Brake test inactive, wait until SBT is selected
1: Setpoint input drive
2: Determining the load
3: Brake test is initialized, wait for test sequence start
4: Start test sequence
5: Close the brake, establish the test torque
6: Brake test active, wait until the test has been completed
7: Reduce test torque to zero
8: Wait for the brake to open
9: Brake test successfully completed, wait until start is deselected
10: Change to brake test initialized - - fault acknowledgment
11: Brake test canceled, torque is reduced to zero
12: Brake test canceled, wait for the brake to open
13: Brake test exited with error, wait for acknowledgment
14: Brake opening timer expired
15: Error when initializing the brake test, wait for acknowledgment
16: Change to brake test inactive, acknowledgment active
Unit:
Default value:
- -
- -
p10250
CI: SI Safety Control Channel control word S_STW1B
Sets the signal source for control word S_STW1B of the Safety Control
Channel.
See also: p10203,r10251
Unit:
Default value:
- -
0
r10251.8...12
CO/BO: SI Safety Control Channel control word S_STW1B diagnostics
Display and BICO output for the diagnostics of control word S_STW1B of the
Safety Control Channel.
Bit signal name
08 Extended Functions test stop selection
1 signal: Selected, 0 signal: Not selected
09 Extended Functions trigger referencing
1 signal: Selected, 0 signal: Not selected
10 Extended Functions trigger reset
1 signal: Selected, 0 signal: Not selected
Extended Functions premature SOS after STOP D
1 signal: Selected, 0 signal: Not selected
Unit:
Default value:
- -
- -
8-492
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Minimum value:
Maximum value:
0
16
Minimum value:
Maximum value:
- -
- -
Minimum value:
Maximum value:
- -
- -
Checksum:
Protection level:
Yes
3
Data type:
Effective:
Integer16
POWER ON
Checksum:
Protection level:
Yes
3
Data type:
Effective:
Unsigned32 /
POWER ON
Integer16
Checksum:
Protection level:
Yes
3
Data type:
Effective:
Unsigned32
POWER ON
© Siemens AG 2015 All Rights Reserved