10388
MD number
Default value: 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
Special cases, errors,...
10389
MD number
Default value: 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
Special cases, errors,...
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
$MN_PROFISAFE_IN_ASSIGN[0...47]
Input assignment $A_INSE to PROFIsafe module
Min. input limit: 0
Protection level: 7/2
Assignment between an ext. SPL interface $A_INSE and a PROFIsafe input module
The SPL area data is specified in the decimal notation in the following format: aaa bbb
withaaa = area limit 1, SPL signal $A_INSE[aaa]
bbb = area limit 2, SPL signal $A_INSE[bbb]
Example:
$MN_PROFISAFE_IN_ASSIGN[0] = 001 004 or alternatively 004 001:
System variables $A_INSE[1...4] are supplied with the state of the input terminals of the
PROFIsafe module, which was parameterized using MD10386 $MN_PROFISAFE_IN_
ADDRESS[0] and selected using MD13300 $MN_PROFISAFE_IN_FILTER[0].
$MN_PROFISAFE_OUT_ASSIGN[0...47]
Output assignment, $A_OUTSE to PROFIsafe module
Min. input limit: 0
Protection level: 7/2
Assignment between an ext. SPL interface $A_OUTSE and a PROFIsafe output module
The SPL area data is specified in the decimal notation in the following format: aaa bbb
with
aaa = area limit 1, SPL signal $A_OUTSE[aaa]
bbb = area limit 2, SPL signal $A_OUTSE[bbb]
Example:
$MN_PROFISAFE_OUT_ASSIGN[0] = 064 061 or alternatively 061 064:
The output terminals selected in MD13301 $MN_PROFISAFE_IN_FILTER[0] of the
PROFIsafe module parameterized using MD10387 $MN_PROFISAFE_OUT_ADDRESS[0]
are supplied with the states of system variables $A_OUTSE[61...64].
8.1 Machine data for SINUMERIK 840D sl
Max. input limit: 192192
Max. input limit: 192192
Data Description
Unit: - -
Unit: - -
8-363