Siemens Sinumerik 840D sl Function Manual page 491

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

10/15
p10234.0...15
CO/BO: SI Safety Info Channel status word S_ZSW3B
Display and BICO output for status word S_ZSW3B of the Safety Info Channel.
Bit signal name
00 brake test selected
1 signal: Yes, 0 signal: No
01 setpoint input drive/external
1 signal: Drive, 0 signal: External
02 active brake
1 signal: Brake 2, 0 signal: Brake 1
03 brake test active
1 signal: Yes, 0 signal: No
04 brake test result
1 signal: Successful, 0 signal: Erroneous
05 brake test completed
1 signal: Yes, 0 signal: No
06 external brake request
1 signal: Close, 0 signal: Open
07 actual load sign
1 signal: Negative, 0 signal: Positive
14 acceptance test SLP (SE) active
1 signal: Yes, 0 signal: No
15 acceptance test mode selected
1 signal: Yes, 0 signal: No
Unit:
Default value:
- -
- -
p10235
CI: SI Safety Control Channel control word S_STW3B
Sets the signal source for control word S_STW3B of the Safety Control Chan-
nel.
This parameter is only used as control word for the safe brake test only for
"SBT via SCC" (p10203 = 0).
See also: p10203
Unit:
Default value:
- -
0
r10240
SI Motion SBT load torque diagnostics
Displays the load torque for the safe brake test.
This load torque is available at the drive when initializing the brake test.
Note
The displayed value is kept until the brake test is deselected.
Unit:
Default value:
Nm
- -
r10241
SI Motion SBT load force diagnostics
Displays the load force for the safe brake test.
This load force is available at the drive when initializing the brake test.
Note
The displayed value is kept until the brake test is deselected.
Unit:
Default value:
N
- -
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Minimum value:
Maximum value:
- -
- -
Minimum value:
Maximum value:
- -
- -
Minimum value:
Maximum value:
- -
- -
Minimum value:
Maximum value:
- -
- -
Data Description
8.2 Parameters for SINAMICS S120
Checksum:
Yes
Data type:
Unsigned32
Checksum:
Yes
Data type:
Unsigned32 /
Integer16
Checksum:
Yes
Data type:
Floating Point32
Checksum:
Yes
Data type:
Floating Point32
Protection level:
3
Effective:
POWER ON
Protection level:
3
Effective:
POWER ON
Protection level:
3
Effective:
POWER ON
Protection level:
3
Effective:
POWER ON
8-491