10/15
37952
MD number
Default value: 1...31
Change becomes effective after: POWER ON
Data type: BYTE
Meaning:
Special cases, errors,...
37954
MD number
Default value: 1...31
Change becomes effective after: POWER ON
Data type: BYTE
Meaning:
Special cases, errors,...
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
$MA_PROFISAFE_MODULE_NR
PROFIsafe module number
Min. input limit: 1
Protection level: 7/2
Number to select a logical basis address from MD13372 $MN_SAFE_PS_DRIVE_
LOGIC_ADDR.
$MA_SAFE_INFO_MODULE_NR
SIC/SCC module number
Min. input limit: 1
Protection level: 7/2
Number to select a logical basis address from MD13374 $MN_SAFE_INFO_DRIVE_
LOGIC_ADDR
8.1 Machine data for SINUMERIK 840D sl
Max. input limit: 31
Max. input limit: 31
Data Description
Unit: - -
Unit: - -