Siemens Sinumerik 840D sl Function Manual page 368

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Data Description
8.1 Machine data for SINUMERIK 840D sl
11604
MD number
Default value: 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional references
13300
MD number
Default value: 0xFFFFFFFF
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional references
8-368
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
$MN_ASUP_START_PRIO_LEVEL
Priorities as of which ASUP_START_MASK takes effect
Min. input limit: 0
Protection level: 7/2
This machine data specifies from which ASUB priority the machine data
ASUP_START_MASK is to be applied. MD ASUP_START_MASK is applied from the level
specified here up to the highest ASUB priority level 1.
MD11602 %MN_ASUP_START_MASK
$MN_PROFISAFE_IN_FILTER[0...47]
F useful (net) data filter IN
Min. input limit: 0
Protection level: 7/2
Filter between F net (useful) data and $A_INSE variables
This machine data is used to define which bits are transferred from the F net data interface
of the PROFIsafe module into the NCK for further processing.
The filtered F net data bits are pushed together inside the NCK to form a bit array without
any gaps (consecutive bit array).
Using machine data MD10388 $MN_PROFISAFE_IN_ASSIGN[n] it is then defined in
which $A_INSE variables the filtered F net data bits should be transferred.
Example:
Note: For reasons of simplicity, only 16 bits are taken into consideration.
Parameter assignment:
$MN_PROFISAFE_IN_FILTER = 1010100101000100
$MN_PROFISAFE_IN_ASSIGN = 011006
n = 16
11
6
|x|x|x|x|x|1|1|1|0|0|1|x|x|x|x|x|
$A_INSE[n], x = not relevant
|0|0|0|0|0|0|0|0|0|0|1|1|1|0|0|1|
NCK internal F net data image
|1|0|1|0|1|0|0|1|0|1|0|0|0|1|0|0|
$MN_PROFISAFE_IN_FILTER
|1|0|1|0|1|0|0|0|0|0|0|0|0|1|0|0|
example of a value available at the F net data interface of the PROFIsafe module
Max. input limit: 128
Max. input limit: 0xFFFFFFFF
1
© Siemens AG 2015 All Rights Reserved
10/15
Unit: - -
Unit: - -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120