Safety Functions integrated in the drive
4.6 Control via terminals on the Control Unit and the power unit
NCU X122.4
DI x
r0722.x
M
Monitoring channel
Control Unit
Monitoring channel
Motor module
Figure 4-2 Terminals for "Safe Torque Off": example for Motor Modules Booksize and NCU7x0
Grouping drives
To ensure that the function works for more than one drive at the same time, the
terminals for the corresponding drives must be grouped together as follows:
S 1. Control Unit shutdown path
By connecting the binector input to the joint input terminal on the drives in one
group.
S 2. Motor Module shutdown path
By appropriately connecting terminal "EP" for the individual Motor Modules be-
longing to a group.
Note
The grouping must be identical in both monitoring channels.
If a fault in a drive results in a Safe Torque Off (STO), this does not automatically
mean that the other drives in the same group also switch to Safe Torque Off
(STO).
The assignment is checked during the test for the switch--off signal paths. The
operator selects Safe Torque Off for each group. The check is drive--specific.
4-70
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
NCU 7x0
DRIVE--CLiQ
BI:
p9620
X21/X22
1
2
3
4
Motor module
DRIVE--CLiQ
DRIVE--CLiQ
U2
V2
Temp +
W2
Temp --
BR+
EP +24 V
BR- -
EP M