Siemens Sinumerik 840D sl Function Manual page 790

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Diagnostics
10.3 Safety messages for SINAMICS S120
F30655
Response
Acknowledgment
Explanation
Remedy
F30656
Response
Acknowledgment
Explanation
Remedy
10-790
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
SI P2: Aligning the monitoring functions
OFF2
IMMEDIATELY (POWER ON)
An error has occurred when aligning the Safety Integrated monitoring
functions for the two monitoring channels. A common set of supported
SI monitoring functions was not able to be determined.
-- DRIVE--CLiQ communications has an error or failed.
-- Safety Integrated software releases on the Control Unit and the
Motor Module/Hydraulic Module are not compatible with one
another.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, interpret as hexadecimal):
Only for internal Siemens troubleshooting.
Carry out a POWER ON (power off/on) for all components
-- Upgrade the Motor Module/Hydraulic Module software.
-- Upgrade the Control Unit software.
-- Check the electrical cabinet design and cable routing for EMC
compliance.
SI P2: Incorrect Motor Module parameter
OFF2
IMMEDIATELY (POWER ON)
When accessing the Safety Integrated parameters for monitoring
channel 2 in the non--volatile memory, an error has occurred.
Note:
This fault results in a STOP A that can be acknowledged.
Fault value (r0949, interpret decimal):
129:
Safety parameters for monitoring channel 2 corrupted.
Drive with enabled safety functions possibly copied offline using the
commissioning software and the project downloaded.
131:
Internal software error on the Control Unit.
255:
Internal Motor Module/Hydraulic Module software error.
Recommission the safety functions.
-- Upgrade the Control Unit software.
-- Upgrade the Motor Module/Hydraulic Module software.
-- Replace the memory card or the Control Unit.
For fault value = 129:
-- Activate the safety commissioning mode (p0010 = 95).
-- Adapt the PROFIsafe address (p9610).
-- Start the copy function for SI parameters (p9700 = D0 hex).
-- Acknowledge data change (p9701 = DC hex).
-- Exit the safety commissioning mode (p0010 = 0).
-- Save all parameters (p0977 = 1 or "Copy RAM to ROM").
-- Carry out a POWER ON (power off/on) for all components.
© Siemens AG 2015 All Rights Reserved
10/15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents