Siemens Sinumerik 840D sl Function Manual page 377

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

10/15
13335
MD number
Default value 0.5
Change becomes effective after: POWER ON
Data type: DOUBLE
Meaning:
corresponds with ...
Additional references
13336
MD number
Default value 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional references
13337
MD number
Default value 0xFFFF
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional references
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
$MN_SAFE_SDP_TIMEOUT[0...15]
Monitoring time for F_SENDDP
Min. input limit: 0.0
Protection level: 7/2
The monitoring time is the time within which the F_SENDDP sends a new F telegram to
F_RECVDP or F_RECVDP must have acknowledged a new F telegram. When the monito-
ring time is exceeded, F_RECVDP outputs substitute values to the SPL.
SIMATIC block parameters: TIMEOUT
$MN_SAFE_SDP_ASSIGN[0...15]
Output assignment $A_OUTSE to F_SENDDP net data
Min. input limit: 0
Protection level: 7/2
The selection of the SPL signals $A_OUTSE in the F_SENDDP net data to be transferred
can only be done area for area.
The SPL area is specified in the decimal notation in the format aaa bbb
with aaa = area limit 1, SPL signal $A_OUTSE[aaa]
bbb = area limit 2, SPL signal $A_OUTSE[bbb]
Example:
$MN_SAFE_SDP_ASSIGN[0] = 001 004 or alternatively 004 001
The SPL signals $A_OUTSE[1] to $A_OUTSE[4] are transferred in the F_SENDDP net
data selected using MD13337 $MN_SAFE_SDP_FILTER[0].
$MN_SAFE_SDP_FILTER[0...15]
F net data filter between $A_OUTSE and F_SENDDP
Min. input limit: 0
Protection level: 7/2
The SPL signals, selected using MD13336 $MN_SAFE_SDP_ASSIGN are transferred in
the F_SENDDP net data signals in the sequence of the filter bits set to 1. The least signifi-
cant SPL signal at the bit position of the F_SENDDP net data of the least significant filter
bits set to 1 etc. for all selected SPL signals.
Bit x = 1
An SPL signal is transferred at the bit position x of the F_SENDDP net data.
Bit x = 0
No SPL signal is transferred at the bit position x of the F_SENDDP net data.
8.1 Machine data for SINUMERIK 840D sl
Max. input limit: 60
Max. input limit: 192192
Max. input limit: 0xFFFF
Data Description
Unit: s
Unit: - -
Unit: - -
8-377