Diagnostics
10.3 Safety messages for SINAMICS S120
F01660
Response for A:
Acknowledgment
Explanation
Remedy
F01664
Response for A:
Acknowledgment
Explanation
10-758
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
For fault value = 3:
-- Simulation mode for the digital input ended (p0795).
Re fault value = 10, 11, 12, 13, 14, 15, 17, 18, 19, 20, 21, 22, 23:
-- Check whether there are faults in the safety function alignment
between the Control Unit and the Motor Module involved (F01655,
F30655) and if required, carry out diagnostics for the faults involved.
-- Use a Motor Module that supports the function "Safe Torque Off",
"Safe Brake Control" PROFIsafe/PROFIsafe V2", "motion monitor-
ing functions integrated in the drive".
-- Upgrade the Motor Module software.
-- Upgrade the Control Unit software.
For fault value = 16:
-- Inhibit the internal voltage protection (p1231).
See also: p9501 (SI Motion enable safe functions), p9601 (SI enable
functions integrated in the drive (Control Unit)), p9620 (SI signal source
for SH/SBC/SS1 (Control Unit)), p9761 (SI password input), p9801
(SI enable functions integrated in the drive (Motor Module))
SI P1 (CU): Safety functions not supported
OFF2
IMMEDIATELY (POWER ON)
The Motor Module/Hydraulic Module does not support the safety--
related functions (e.g. the Motor Module/Hydraulic Module version is
not the correct one).
Safety Integrated cannot be commissioned.
Note:
This fault does not result in a safety stop response.
Use a Motor Module/Hydraulic Module that supports the safety--related
functions.
-- Upgrade the Motor Module/Hydraulic Module software.
SI P1 (CU): No automatic firmware update
OFF2
IMMEDIATELY (POWER ON)
When booting it was identified that function "Automatic firmware
update" (p7826 = 1) was not activated.
However, this is necessary for the automatic firmware update/down-
grade in order to avoid, when enabling the safety functions, an inadmis-
sible combination of versions.
Note:
This fault does not result in a safety stop response.
See also: p7826 (automatic firmware update)