10/15
Information regarding carrying out the acceptance test
S Some of the standard NC monitoring functions, such as zero speed monitoring,
software limit switches, etc. must be de--activated (monitoring limits must be
made less sensitive) before the acceptance test is carried out.
The function sequences can be acquired and listed using the servo trace
function or using the D/A converter output.
S After the SPL has been commissioned the access authorization for the NCK--
SPL (SAFE.SPF) via the user interface must be reduced to the manufacturer or
service level.
S Please refer to the information in Chapter 9.2, "Procedure when commissioning
for the first time".
S The acceptance report comprises checking the alarm displays and including the
alarm reports in the overall acceptance report. In order to obtain reproducible
and comparable alarm displays, MD10094 $MN_SAFE_ALARM_SUP-
PRESS_LEVEL must be set to 0 during the acceptance test in order to avoid
suppressing alarm outputs.
S For SINUMERIK 840D sl, to document a test stop that has been carried out,
it is sufficient to just log the test stop alarms of the NCK (27002); it is not abso-
lutely necessary to log the test stop alarms of the SINAMICS S120 (C01798).
Authorized person, acceptance report
The test of each SI function must be carried out by an authorized person and
logged in the acceptance report. The report must be signed by the person who
carried out the acceptance tests.
Authorized in this sense refers to a person who has the necessary technical
training and knowledge of the safety functions and is authorized by the machine
manufacturer to carry out the test.
Documentation, data archiving
The results of the acceptance test as well as all hardware and software changes
as shown in the table 9-1 should be documented in a suitable form.
In addition to the acceptance report, the following SI relevant data must be
archived:
NC machine data
Drive parameters
PLC--/NCK--SPL program
PLC project