Corrective maintenance
10.2 Replacing spare parts
6. Remove 2 screws (TX-25).
7. Remove the fan.
The fan is removed.
Installing the fan
1. Mount the fan into the converter.
2. Tighten 2 fan screws (TX-25).
3. Plug the fan connector.
4. Mount the front cover.
5. Tighten 2 screws (TX-25) of the front cover.
6. Mount the terminal covers.
7. Tighten the screws (TX-25) of the upper and lower terminal cover.
The fan is installed.