Commissioning Of Safety Integrated Functions; General Information - Siemens Sinamics S110 Function Manual

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Safety Integrated Functions
8.7 Commissioning
8.7.2

Commissioning of Safety Integrated functions

8.7.2.1

General information

PROFIsafe commissioning with STARTER
1. The Safety Integrated Basic Functions can be commissioned using STARTER in three
2. The Safety Integrated Extended Functions can be commissioned using STARTER in
There follows a brief overview of the STARTER functionality which enables Safety Integrated
Functions to be used by means of terminals, PROFIsafe, or a combination of the two.
Safety slot
In order to use Safety Integrated functions via PROFIBUS or PROFINET, a safety slot must
first be created using SIMATIC Manager Step 7 and HW Config. The procedure to do this
was described in the previous chapters.
Expert list
The Safety Integrated Basic Functions can be individually and manually set using the Expert
list; the settings using the STARTER screen forms, however, are more user-friendly and you
are less prone to making mistakes.
428
ways:
– STO/SS1/SBC via terminals
– STO/SS1/SBC via PROFIsafe
– STO/SS1/SBC via PROFIsafe and terminals simultaneously
three ways:
– Motion Monitoring via terminal
– Motion monitoring via PROFIsafe
– Motion monitoring via PROFIsafe and terminal simultaneously
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Function Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents