Siemens Sinamics S110 Function Manual page 674

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Basic information about the drive system
10.3 Working with the memory card
Firmware version
+ parameter backup
both on own
memory
card
Yes
Insert memory card with
firmware into
CU305
Switch SINAMICS S110
off and on
again
Firmware is
copied from memory
card
to CU305
Log off and remove memory
card with firmware and
insert card with
parameter
backup into
CU305
Switch SINAMICS S110
off and on
again
Parameter backup
with index 0 is
copied from the
memory card
to CU305
Log memory card
off (p9400 = 2)
and remove it
from CU305
Figure 10-7
Replacing the device
672
Firmware version
on memory card =
No
firmware version
on CU305
Yes
Insert memory card with
parameter backup
into CU305
Switch SINAMICS S110
off and on
again
Parameter backup
with index 0 is
copied from the
memory card
to CU305
Log memory card
off (p9400 = 2)
and remove it
from CU305
No
Caution:
Any existing parameter backup on CU305
will be overwritten if
setting is 0!
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Insert memory card with
firmware into
CU305
Switch SINAMICS S110
off and on
again
Firmware is
copied from memory
card
to CU305
Log memory card
off (p9400 = 2)
and remove it
from CU305
Copy parameter
backup to CU305:
See section 10.3.1
Marginal note "Series
commissioning
(copy parameter set)"
Function Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents