Function diagram (see SINAMICS S110 List Manual)
● 5301 Servo control - variable signaling function
Overview of important parameters (see SINAMICS S110 List Manual)
● p3290 Variable signaling function start
● p3291 Variable signaling function signal source
● p3292 Variable signaling function signal source address
● p3293 Variable signaling function signal source data type
● p3294 Variable signaling function output signal
● p3295 Variable signaling function threshold value
● p3296 Variable signaling function hysteresis
● p3297 Variable signaling function pull-in delay [ms]
● p3298 Variable signaling function drop-out delay [ms]
● p3299 Variable signaling function sampling time
Note:
The variable signaling function works with an accuracy of 8 ms (also to be taken into account
for pull-in and drop-out delay).