Safety Integrated Functions
8.5 Safety Integrated Extended Functions
Figure 8-12
Safe Brake Ramp without encoder (for SLS)
Parameterization of the brake ramp
p9581/p9381 (SI Motion brake ramp reference value, Control Unit/Motor Module) and
p9583/p9383 (SI Motion brake ramp monitoring time, Control Unit/Motor Module) are used to
set the steepness of the brake ramp. Parameters p9581/p9381 determine the reference
speed and parameters p9583/p9383 define the ramp-down time. Parameters p9582/p9382
are used to set the time which passes after the triggering of SS1, selection of SLS or SLS
level changeover and the start of brake ramp monitoring.