7.3.7.4

Fixed speed setpoints

Description
This function can be used to specify preset speed setpoints. The fixed setpoints are defined
in parameters and selected via binector inputs. Both the individual fixed setpoints and the
effective fixed setpoint are available for further interconnection via a connector output (e.g. to
connector input p1070 - CI: main setpoint).
Properties
● Number of fixed setpoints: Fixed setpoint 1 to 15
● Selection of fixed setpoints: Binector input bits 0 to 3
Function diagrams (see SINAMICS S110 List Manual)
● 1550 Overviews - setpoint channel
● 3010 Fixed speed setpoints
Overview of important parameters (see SINAMICS S110 List Manual)
Adjustable parameters
● p1001[D] CO: Fixed speed setpoint 1
● ...
● p1004[D] CO: Fixed speed setpoint 4
● p1020[C] BI: Fixed speed setpoint selection Bit 0
● p1021[C] BI: Fixed speed setpoint selection Bit 1
Display parameters
● r1024 CO: Fixed speed setpoint effective
● r1197 Fixed speed setpoint current number
Parameterization with STARTER
The "fixed setpoints" parameter screen is activated in the project navigator under the
relevant drive by double-clicking Setpoint channel → Fixed setpoints in the STARTER
commissioning tool.
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
– Binector input bits 0, 1, 2, and 3 = 0 → setpoint = 0 active
– Unused binector inputs have the same effect as a "0" signal
Drive functions
7.3 Function modules