Drive functions
7.3 Function modules
Control and status messages
Table 7- 27
Jog control
Signal name
0 = OFF1
0 = OFF2
0 = OFF3
Enable operation
Jog 1
Jog 2
Table 7- 28
Jog status message
Signal name
Ready to start
Ready for operation
Operation enabled
Switching on inhibited
Pulses enabled
Function diagrams (see SINAMICS S110 List Manual)
● 2610 Sequence control - sequencer
● 3030 Setpoint addition, setpoint scaling, jog
Overview of important parameters (see SINAMICS S110 List Manual)
● p1055[C] BI: Jog bit 0
● p1056[C] BI: Jog bit 1
● p1058[D] Jog 1 speed setpoint
● p1059[D] Jog 2 speed setpoint
● p1082[D] Maximum speed
● p1120[D] Ramp-function generator ramp-up time
● p1121[D] Ramp-function generator ramp-down time
Parameterization with STARTER
The "speed setpoint" parameter screen is selected via the following icon in the toolbar of the
STARTER commissioning tool.
Figure 7-59
274
Internal control word
STWA.0
STWA.1
STWA.2
STWA.3
STWA.8
STWA.9
Internal status word
ZSWA.0
ZSWA.1
ZSWA.2
ZSWA.6
ZSWA.11
STARTER icon for "speed setpoint"
Binector input
p0840 ON/OFF1
p0844 1. OFF2
p0845 2. OFF2
p0848 1. OFF3
p0849 2. OFF3
p0852 Enable operation
p1055 Jog bit 0
p1056 Jog bit 1
Parameter
r0899.0
r0899.1
r0899.2
r0899.6
r0899.11
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
PROFIdrive/Siemens
telegram 1 ... 111
STW1.0
STW1.1
STW1.2
STW1.3
STW1.8
STW1.9
PROFIdrive/Siemens
telegram 1 ... 111
ZSW1.0
ZSW1.1
ZSW1.2
ZSW1.6
ZSW1.11
Function Manual