Example 2: Write Parameters (Multi-Parameter Request) - Siemens Sinamics S110 Function Manual

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Communication
9.2 Communication according to PROFIdrive
9.2.4.5

Example 2: write parameters (multi-parameter request)

Requirements
1. The PROFIdrive controller has been commissioned and is fully operational.
2. PROFIdrive communication between the controller and the device is operational.
3. The controller can read and write data sets in conformance with PROFIdrive DPV1.
4. Control type: Servo with activated "Extended setpoint channel" function module
Task description
Jog 1 and 2 are to be set up for drive 2 (also drive object number 2) via the input terminals of
the Control Unit. A parameter request is to be used to write the corresponding parameters as
follows:
 BI: p1055 = r0722.3
 BI: p1056 = r0722.4
 p1058 = 300 1/min
 p1059 = 600 1/min
The request is to be handled using a request and response data block.
Figure 9-18
Basic procedure
1. Create a request to write the parameters.
586
Special requirements for this example:
Task description for multi-parameter request (example)
Jog bit 0
Jog bit 1
Jog 1 speed setpoint
Jog 2 speed setpoint
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Function Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents