Drive functions
7.1 Servo control
Rating plate data
Input of the rating plate data requires the following parameters:
Table 7- 9
Rating plate data
Induction motor
p0304 Motor rated voltage
p0305 Motor rated current
p0307 Motor rated power
p0308 Motor rated power factor
p0310 Motor rated frequency
p0311 Motor rated speed
p0322 Maximum motor speed
p0353 Motor series inductance
p0400ff Encoder data
Since the rating plate data contains the initialization values for identification, you must
ensure that it is entered correctly and consistently to enable the above data to be
determined.
Parameters to control the MotID
The following parameters influence the MotID:
Table 7- 10
Parameters for control
Static measurement (motor data identification)
p0640 Current limit
p1215 Motor holding brake configuration
p1909 Motor data identification control word
p1910 Motor data identification, stationary
p1959.14/.15 Positive/negative direction permitted*
Note:
If a brake is being used and is operational (p1215 = 1, 3), then the stationary measurement with closed brake is carried
out. If possible (e.g. no hanging/suspended axis), we recommend that the brake is opened before the MotID (p1215 = 2).
This also means that the encoder size can be adjusted and the angular commutation calibrated.
*The p1959 setting has the following effects on the rotational direction parameter p1821:
Positive direction permitted, with setting p1821=0 means: Clockwise direction of rotation
Negative direction permitted, with setting p1821=1 means: Counter-clockwise direction of rotation
156
Permanent-magnet synchronous motor
p0304 Motor rated voltage
p0305 Motor rated current
p0307 Motor rated power (alternative p0316)
p0311 Motor rated speed
p0314 Motor pole pair number
or p0315 Motor pole pair width
p0322 Maximum motor speed
p0323 Maximum motor current
p0353 Motor series inductance
p0400ff Encoder data
Rotating measurement
p0640 Current limit
p1082 Maximum speed
p1958 motor data identification ramp-up/ramp-down time
p1959 Rotating measurement configuration
p1960 Rotating measurement selection
Function Manual, 01/2011, 6SL3097-4AB10-0BP3