Off3 Torque Limits - Siemens Sinamics S110 Function Manual

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Drive functions
7.2 Basic functions
7.2.5

OFF3 torque limits

Description
If the torque limits are externally specified (e.g. tension controller), then the drive can only be
stopped with a reduced torque.
In order to avoid this, there is a binector input (p1551), that for a LOW signal, activates the
torque limits p1520 and p1521. This means that the drive can brake with the maximum
torque by interconnecting the signal OFF 3 (r0899.5) to this binector.
Figure 7-30
Function diagrams (see SINAMICS S110 List Manual)
● 5620 Motor/generator torque limits
● 5630 Upper/lower torque limit
Overview of important parameters (see SINAMICS S110 List Manual)
● p1520 Torque limit, upper/motoring
● p1521 Torque limit, lower/regenerative
196
Torque limits OFF3
Function Manual, 01/2011, 6SL3097-4AB10-0BP3