Important functions via BOP20

Description
Using the BOP20, the following functions can be executed via parameters that support you
when handling projects:
● Restoring the factory settings
● Copy RAM to ROM
● Acknowledge error
Restoring the factory settings
The factory setting of the complete device can be established in the drive object CU.
● p0009 = 30
● p0976 = 1
Copy RAM to ROM
You can initiate the saving of all parameters to the non-volatile memory in the drive object
CU:
● Press the P key for 3 seconds,
● p0009 = 0
● p0977 = 1
Acknowledge error
To acknowledge all the faults that have been rectified, press the Fn key.
52
or
NOTICE
This parameter is not accepted if an identification run (e.g. motor identification) has
been selected on a drive.