Drive functions
7.3 Function modules
Function diagrams (see SINAMICS S110 List Manual)
● 1550 Setpoint channel
● 3060 Basic ramp-function generator
● 3070 Extended ramp-function generator
● 3080 Ramp-function generator selection, status word, tracking
Signal overview (see SINAMICS S110 List Manual)
● Control signal STW1.2 OFF3
● Control signal STW1.4 Enable ramp-function generator
● Control signal STW1.5 Start/stop ramp-function generator
● Control signal STW1.6 Enable setpoint
● Control signal STW2.1 Bypass ramp-function generator
Parameterization with STARTER
The "ramp-function generator" parameter screen is selected via the following icon in the
toolbar of the STARTER commissioning tool:
Figure 7-67
Overview of important parameters (see SINAMICS S110 List Manual)
Adjustable parameters
● p1115 Ramp-function generator selection
● p1120[D] Ramp-function generator ramp-up time
● p1121[D] Ramp-function generator ramp-down time
● p1122[C] BI: Bypass ramp-function generator
● p1130[D] Ramp-function generator initial rounding time
● p1131[D] Ramp-function generator final rounding time
● p1134[D] Ramp-function generator rounding type
● p1135[D] OFF3 ramp-down time
● p1136[D] OFF3 initial rounding time
● p1137[D] OFF3 final rounding time
● p1140[C] BI: Enable ramp-function generator
● p1141[C] BI: Start ramp-function generator
● p1143[C] BI: Ramp-function generator, accept setting value
286
STARTER icon for "ramp-function generator"
Function Manual, 01/2011, 6SL3097-4AB10-0BP3