Overview of important parameters (see SINAMICS S110 List Manual)
Adjustable parameters
● p0130 Motor data sets (MDS) number
● p0139 Copy motor data set (MDS)
● p0140 Encoder data sets (EDS) number
● p0180 Drive data sets (DDS) number
● p0186 Motor data set (MDS) number
● p0187 Encoder 1 encoder data set number
● p0188 Encoder 2 encoder data set number
● p0809 Copy command data set (CDS)
● p0810 BI: Command data set selection CDS bit 0
● p0819[0...2] Copy drive data set DDS
● p0820 BI: Drive data set selection DDS, bit 0
10.2.6

Using data sets

Copying a command data set
Set parameter p0809 as follows:
1. p0809[0] = number of the command data set to be copied (source)
2. p0809[1] = number of the command data to which the data is to be copied (target)
3. p0809[2] = 1
Start copying.
Copying is finished when p0809[2] = 0.
Note
In STARTER, you can copy the command data sets (Drive → Configuration → "Command
data sets" tab).
You can select the displayed command data set in the relevant STARTER screens.
Copying a drive data set
Set parameter p0819 as follows:
1. p0819[0] = Number of the drive data set to be copied (source)
2. p0819[1] = Number of the drive data set to which the data is to be copied (target)
3. p0819[2] = 1
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Basic information about the drive system
10.2 Data sets