Displays And Using The Bop20 - Siemens Sinamics S110 Function Manual

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

BOP20 functions
Table 6- 3
Functions
Name
Units
Access level
Unplug while voltage is
present
Actuating keys
Parameters for BOP
Drive object, Control Unit
● p0003 BOP access level
● p0009 Device commissioning, parameter filter
● r0019 CO/BO: Control word, BOP
● p0977 Save all parameters
SERVO drive object
● p0010 Commissioning parameter filter
6.2

Displays and using the BOP20

Features
● Operating display
● Changing the active drive object
● Displaying/changing parameters
● Displaying/acknowledging faults and alarms
● Controlling the drive using the BOP20
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
The units are not displayed on the BOP.
The access level for the BOP is defined using p0003.
The higher the access level, the more parameters can be selected using the BOP.
The BOP can be withdrawn and inserted under voltage.
The ON and OFF keys have a function.
When withdrawing, the drive is stopped.
Once the BOP has been inserted, the drive must be switched on again.
.
ON and OFF keys have no function
Withdrawing and inserting has no effect on the drive.
The following applies to the "P" and "FN" keys:
When used in a combination with another key, "P" or "FN" must be pressed first and then
the other key.
Parameterization using the Basic Operator Panel 20
6.2 Displays and using the BOP20
Description
117

Hide quick links:

Advertisement

Table of Contents
loading