Drive functions
7.3 Function modules
7.3.7.7
Direction limitation and setpoint inversion
Description
A reverse operation involves a direction reversal. Selecting setpoint inversion p1113[C] can
reverse the direction in the setpoint channel.
Parameter p1110[C] or p1111[C] can be set respectively to prevent input of a negative or
positive setpoint via the setpoint channel. However, the following settings for minimum speed
(p1080) in the setpoint channel are still operative. With the minimum speed, the motor can
turn in a negative direction, although p1110 = 1 is set.
Figure 7-61
Function diagrams (see SINAMICS S110 List Manual)
● 1550 Setpoint channel
● 3040 Direction limitation and direction reversal
Overview of important parameters (see SINAMICS S110 List Manual)
Adjustable parameters
● p1110[C] BI: Inhibit negative direction
● p1111[C] BI: Inhibit positive direction
● p1113[C] BI: Setpoint inversion
280
Direction of rotation limiting and direction of rotation changeover
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Function Manual