The stationary MotID can result in slight movement of up to 210 degrees electrical.
For the rotating motor data identification routine, motor motion is initiated capable of
reaching the maximum speed (p1082) and the motor torque corresponding to the maximum
current (p0640).
The rotating measurement should be carried out with a motor running at no load (de-
coupled from the mechanical system) in order to prevent damage/destruction to the load or
be influenced by the load. If the motor cannot be de-coupled from the mechanical system,
then the stress on the mechanical system can be reduced by parameterizing the ramp-up
time (p1958) and/or using a speed limit (p1959.14/p1959.15) or using the current and
speed limit.
If a mechanical distance limit has been set, you are advised not to carry out the rotating
measurement.
The emergency shutdown functions must be fully operational during commissioning.
To protect the machines and personnel, the relevant safety regulations must be observed.
Motor data
Motor data input requires the following parameters:
Table 7- 8
Motor data
Induction motor
p0304 Motor rated voltage
p0305 Motor rated current
p0307 Motor rated power
p0308 Motor rated power factor
p0310 Motor rated frequency
p0311 Motor rated speed
p0320 Motor rated magnetizing current
p0322 Maximum motor speed
p0350 Motor stator resistance, cold
p0353 Motor series inductance
p0354 Motor rotor resistance, cold
p0356 Motor stator leakage inductance
p0358 Motor rotor leakage inductance
p0360 Motor magnetizing inductance
p0400ff Encoder data
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
DANGER
Permanent-magnet synchronous motor
p0305 Motor rated current
p0311 Motor rated speed
p0314 Motor pole pair number
p0316 Motor torque constant
p0322 Maximum motor speed
p0323 Maximum motor current
p0341 Motor moment of inertia
p0350 Motor stator resistance, cold
p0353 Motor series inductance
p0356 Motor stator leakage inductance
p0400ff Encoder data
Drive functions
7.1 Servo control
155